Power Conditioner, Voltage Regulator, & Battery Backup UPS For Eppendorf ThermoMixer CThe battery backup UPS (uninterruptible power supply) and power conditioner for the Eppendorf ThermoMixer C provides automatic seamless emergency backup power to the instrument. Plug the battery backup UPS into an available wall socket, then plug the Eppendorf ThermoMixer C into one of the available receptacles on the back of the battery backup UPS, turn it on, and forget about it. If utility power is lost while the Eppendorf ThermoMixer C is on and
4 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology (Phase Locked To Utility Power Allowing Seamless Transition To Backup Power).
Multiple Backup Time Options:
| Model Number: | Description (Under Battery Options Drop Down): | Approximate Backup Time With Eppendorf ThermoMixer C: |
| BBP-AR-1000-PSW-ONL | UPS With Internal Batteries Only | 31 Minutes |
| BBP-AR-1000-PSW-ONL-WEBP | UPS Plus 1 Extra External Battery Pack | 2 Hours 38 Minutes |
| BBP-AR-1000-PSW-ONL-W2EBP | UPS Plus 2 Extra External Battery Packs | 4 Hours 45 Minutes |
- 1000 VA (1 kVA) / 900 Watt (0.9 kW)
- 55-150 Volt AC Input / 100/110/115/120/127 Volt AC Output
- Energy Efficient/High Efficiency UPS Mode >96.5% Efficiency When Enabled
- LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time
- Tower
- Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
- Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source)
- Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS)
- Constant Voltage Regulation (±1%)
- Constant Frequency Regulation (±1 or ±3% Selectable)
- Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
- Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries
- Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration
- >0.99 Input Power Factor / 0.92 Output Power Factor (Line Mode) / 0.965 Output Power Factor (High Efficiency Mode) For Superior Efficiency And Power Savings
- INPUT: 120 Volt, 15 Amp NEMA 5-15P (Standard Wall Plug)
- OUTPUT: 6x 120 Volt, NEMA 5-15R Battery & Surge Protected Receptacles (Standard Wall Receptacles)
- Full Load (900 Watts) Estimated Run Time On Battery Power:
- Up To 11 Minutes On Internal Batteries
- 2 Batteries, 12 Volts, 9 Amp Hours Each
- Up To 58 Minutes On Internal Batteries + 1 Battery Pack
- 10 Batteries, 12 Volts, 9 Amp Hours Each
- Up To 1 Hour 44 Minutes On Internal Batteries + 2 Battery Packs
- 18 Batteries, 12 Volts, 9 Amp Hours Each
- Half Load (450 Watts) Estimated Run Time On Battery Power:
- Up To 23 Minutes On Internal Batteries
- 2 Batteries, 12 Volts, 9 Amp Hours Each
- Up To 1 Hours 56 Minutes On Internal Batteries + 1 Battery Pack
- 10 Batteries, 12 Volts, 9 Amp Hours Each
- Up To 3 Hours 29 Minutes On Internal Batteries + 2 Battery Packs
- 18 Batteries, 12 Volts, 9 Amp Hours Each
- Weight: 27.1 lbs.
- Dimensions (Inches): 6.1 X 10.2 X 15.9 (W x H x D)
- Operating Temperature: 32°-104° F
- Operating Humidity: 20%~95%, Non-Condensing
- Operating Elevation: 3,280 Feet Without De-Rating
- Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
- cTUVus, cULus, and FCC Certified
- Includes Software For Windows Monitoring & Configuration
- Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders)
User Guides:
-Battery Backup Power Tower UPS User Guide.pdf
-Battery Backup Power Tower External Battery Pack User Guide.pdf
Spec Sheet/Cut Sheet:
-BBP Tower DSP Series Specification Sheet.pdf
Replacement Batteries:
-Leoch DJW12-9.0 (Lead Acid), Yuasa 7.5-12 (Lead Acid), Yuasa REW45-12 (Lead Acid), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy