UA-Glo® AMP Assay Kit
SKU: 47223122330

UA-Glo® AMP Assay Kit

Sale price$367.20 Regular price$408.00
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 4 - Jul 9

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

UA-Glo® AMP Assay KitProduct Specification Synonyms AMP Assay Kit Stability & Storage Dry ice transportation. Store in the dark at 20 or below. Valid for 12 months. Background The UA Glo AMP Assay Kit enables homogeneous quantitative measurement of the activity of any enzyme that generates AMP in enzymatic assays, such as cAMP specific phosphodiesterase (PDE), aminoacyl tRNA synthetase, T4 DNA ligase, and ubiquitin ligase. This kit determines enzyme activity by

Product Specification


Synonyms AMP Assay Kit
Stability & Storage

Dry ice transportation. Store in the dark at -20℃ or below. Valid for 12 months.

Background

The UA-Glo® AMP Assay Kit enables homogeneous quantitative measurement of the activity of any enzyme that generates AMP in enzymatic assays, such as cAMP-specific phosphodiesterase (PDE), aminoacyl-tRNA synthetase, T4 DNA ligase, and ubiquitin ligase. This kit determines enzyme activity by quantitatively detecting the amount of AMP produced in the enzymatic reaction: the amount of AMP is positively correlated with enzyme activity, and the assay can quantitatively measure AMP generated in the presence or absence of ATP during the reaction. The kit can be used for high-throughput homogeneous screening of inhibitors targeting AMP-producing enzymes, such as PDE. The AMP detection assay offers broad applicability, high detection sensitivity, a wide dynamic range, and strong resistance to compound interference.

Components

The AMP Assay Kit consists of two main components: the AMP GR Reagent and the AMP Detection Reagent, and also includes one vial each of ATP and AMP reagents.
The AMP GR Reagent is used to terminate the enzyme reaction, remove ATP, and convert AMP to ADP.
The AMP Detection Reagent is used to convert ADP to ATP, generating a luminescent signal through the reaction of luciferase with ATP.
The kit specifications are as follows:

Size

Contain

96-well reaction number

384-well reaction number

1,000 assays

AMP GR 5mL

AMP Assay10ml

ATP (10mM, 0.5mL)

AMP (10mM, 0.1mL)

200

1,000

10,000 assays

AMP GR 50mL

AMP Assay100ml

ATP (10mM, 5mL)

AMP (10mM, 1mL)

2,000

10,000


Protocol

1. Enzyme Reaction Setup:

  1. Perform the enzyme reaction in a white opaque 96-well or 384-well assay plate. The recommended reaction volume is 25 µL for 96-well plates and 5 µL for 384-well plates. Test compounds with concentration gradients may be added to the enzyme reaction.

  2. Enzyme and substrate concentrations should be optimized for different enzymatic reactions. To achieve an appropriate signal-to-noise ratio, use enzyme concentrations within the linear response range. Due to the high sensitivity of the AMP Assay Kit, the amount of enzyme required can be significantly reduced.

  3. If the enzyme reaction requires ATP, use high-purity ATP for optimal results. Some commercially available ATP contains residual ADP, which may lead to high background due to the high sensitivity of the AMP Assay Kit. It is recommended to use the ATP provided in the kit or other high-purity ATP, such as Sigma-Aldrich ATP (Cat# A2383, purity ≥99%) or equivalent.

  4. The enzyme reaction may be performed using buffer systems and cofactors reported in the literature or optimized for specific experimental conditions.

  5. The temperature and duration of the enzyme reaction should be set according to the specific enzyme. For high-throughput compound screening, it is recommended to optimize the reaction at room temperature (22°C–25°C) to ensure temperature uniformity during AMP detection.

  6. No additional reagent is required to terminate the enzyme reaction after incubation. If a termination reagent is necessary for specific experimental requirements, avoid using magnesium chelators such as EDTA. The AMP detection reaction requires magnesium ions, and the final concentration must be at least 5 mM.

2. Conversion of AMP to ADP and ATP Removal After Enzyme Reaction:

  1. Take out the AMP GR Reagent and equilibrate it to room temperature (22°C–25°C). Mix gently by swirling [Note 1, 2, 3].

  2. If the enzyme reaction was performed at a non-room temperature (e.g., 30°C), equilibrate the assay plate to room temperature [Note 4].

  3. Add 25 µL of AMP GR Reagent to the 25 µL reaction in a 96-well plate (total volume 50 µL), or 5 µL of AMP GR Reagent to the 5 µL reaction in a 384-well plate (total volume 10 µL). Mix thoroughly by shaking [Note 5].

  4. Incubate at room temperature for 40 minutes.

3. Enzyme Activity Measurement:

  1. Take out the AMP Detection Reagent and equilibrate it to room temperature. Mix gently by swirling [Note 4].

  2. Add 50 µL of AMP Detection Reagent to the 50 µL mixture in the 96-well plate, or 10 µL of AMP Detection Reagent to the 10 µL mixture in the 384-well plate. Mix thoroughly by shaking. Incubate in the dark at room temperature for 30 minutes.

  3. Luminescence signals can be read 30–180 minutes after adding the AMP Detection Reagent, or even longer [Note 6].


Guidelines

1)After first use, the reagent should be aliquoted and stored protected from light at -20°C or below to ensure stability.
2)For long-term storage at -20°C, the AMP Detection Reagent may form a small amount of precipitate after thawing to room temperature. The supernatant can be used directly, or the precipitate can be removed by centrifugation before use.
3) Mixing different batches is not recommended.
4)The luciferase reaction in the AMP Detection Reagent is sensitive to temperature changes. Both the reagent and test samples/assay plates must be equilibrated to room temperature (22°C–25°C), and the temperature should remain constant (±1°C) during the testing process.
5)Unless validated, changing the recommended reagent volumes is not advised. The volume ratio of the enzyme reaction, AMP GR Reagent, and AMP Detection Reagent should be maintained at 1:1:2.
6) The luminescence signal is highly stable and remains essentially unchanged for up to 3 hours.
7)This product is intended for research use only.

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 47223122330

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.3 ★★★★★
Based on 1131 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
A
Verified Purchase
Adam Ladd
Phoenix, US
★★★★★ 5
Great breath freshener on the go
Color: Refreshing Mouthwash, Size: 0.41 Fl Oz (Pack of 30)
Amazing product. Very convienent and easy to use on the go when you need a quick freshen up. Good also if you are out dining with people and eat something with strong flavors (garlic, onion, etc).
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on July 8, 2025
A
Verified Purchase
AFyffe
West Palm Beach, US
★★★★★ 5
Travel mouth wash
Color: Refreshing Mouthwash, Size: 0.41 Fl Oz (Pack of 30)
Absolutely love these travel mouthwash packets! With Invisalign I’m constantly brushing and finishing. The little packets are so convenient to carry in my purse or work bag!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 2, 2026
R
Verified Purchase
Rambo
Waukegan, US
★★★★★ 3
Practical for the size but doesn't last
Color: Refreshing Mouthwash, Size: 0.41 Fl Oz (Pack of 30)
Good for travellers and easy to use. It doesn't take too much space in your bag, but it doesn't last long enough
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 2, 2026
C
Verified Purchase
Chelsea Slay
Port Orchard, US
★★★★★ 5
As a hygienist I love this
Flavor Name: Coconut Mint, Size: 8 Ounce
As a dental hygienist, I’m always cautious about oral care products that claim to whiten while also protecting enamel, but I’ve been pleasantly surprised by this Nano-Hydroxyapatite Oil Pulling Mouthwash. The formula feels gentle yet effective, and I appreciate that it focuses on supporting enamel health instead of relying on harsh whitening ingredients that can increase sensitivity. The nano-hydroxyapatite is a great addition because it helps strengthen and remineralize teeth, which is especially beneficial for patients with sensitivity or early enamel wear. I also noticed my mouth felt very clean and refreshed after use, without the heavy, greasy texture that many oil pulling products tend to leave behind. Another big plus is how well it helps with bad breath and plaque control. It leaves a smooth, fresh feeling without burning or overpowering mint flavors, making it suitable for both adults and older kids. The whitening effect is gradual and natural-looking rather than overly aggressive, which I personally prefer from a dental health standpoint. Overall, this is a well-balanced oral care product that combines natural ingredients with science-backed enamel support. I would definitely recommend it as part of a good brushing and flossing routine.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 15, 2026
K
Verified Purchase
Kelsie
Cuba, US
★★★★★ 5
Love this mouth rinse!
Flavor Name: Coconut Mint, Size: 8 Ounce
Awesome stuff, my new favorite mouth wash leaves breath feeling fresh for a long time and my teeth feel smooth and extra clean all day!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 27, 2026

recommand products